Search
Wish list
Region
Region (us)
Products
Company
Focus on
Contact
de  en  pl  fr  hr  nl  hu  it  sv  sl  cn  es
Press and drag mouse button

Double wall insert

for setting in concrete

HSI150 K2/X

For the gastight and watertight connection on both sides of system seals for cables and cable ducts and maximum flexibility for subsequent use.

Single wall insert with plug-in socket

for setting in concrete and connecting smooth cable ducts

HSI150 GSM

Für den beidseitigen gas- und wasserdichten Anschluss von Systemabdichtungen für Kabel und Kabelschutzrohre und eine maximale Flexibilität bei der späteren Nutzung.

Polymer flange

for retrofit dowelling

HSI150 DFK

For retrofit dowelling via core drill holes or for screwing onto housings. Used for the gastight and watertight connection of system seals for cables and cable ducts.

Double wall insert

for setting in concrete

HSI90 K2/X

For the gastight and watertight connection on both sides of system covers for cables and cable ducts and maximum flexibility for subsequent use.

System cover

cable seal with hot shrink-fit method

HSI150 D WS

For use in wall insert and plastic flange HSI150. The thermal sleeves support a wide area of application, they are shrunk onto the cables by means of the application of heat from the system cover socket. Empty system cover sockets can be sealed with blind plugs.

Closing cover

for empty wall inserts and plastic flanges

HSI150 DT

For pressure-tight sealing of wall inserts that are not in use and plastic flange of the HSI150 system.

Insulated earthing entry

HEA IS

Specifically for station construction. Installed during formwork work. Earthing connections to the building can be made with the thread on both sides in the electrically isolated conductor core.

Double wall insert

for setting in concrete

HSI150 K2/X

For the gastight and watertight connection on both sides of system seals for cables and cable ducts and maximum flexibility for subsequent use.

Split system cover

for retrofit sealing

HSI150 DG

For use in wall insert and polymer flange HSI150. Split design for sealing new cables to be installed or cables that have already been laid.

Individual press seal

for micro pipes and empty conduits

HRD150 b60 A2/EPDM55

Individual press seal in a closed design to seal micro pipes or empty conduits.

Site power supply entry

for secondary substations

BD

Zur temporären Stromversorgung bzw. Notversorgung von Transformatorenstationen. Mit der Baustromdurchführung können Kabel während Baumaßnahmen oberirdisch in die Station eingeführt werden. Die Stationstüren können somit geschlossen werden.

SEGMENTO

Segments for installation in HSI150 S3 system cover

SEG

For particularly gentle sealing of micropipes and control lines.

 Close

Roof entries

Sealing cables and lines for solar, HVAC and mobile communications systems pose our customers with major challenges every single time. Hauff-Technik can offer roof entries like the SHD swan neck entry or HRD-FUFF(A) wall sleeves with fixed/loose flange that are tailor-made to provide the best possible solution for the corresponding roof construction and customer-specific application. The seals between the building and the cables and lines are established with press seals tailor-made specifically to meet customer requirements. We are happy to propose other solutions on request.

Roof entries

Roof Entries by Hauff-Technik for the Safe Introduction of Cables and Lines

As more technology is being installed on rooftops today, the need for roof entries has also increased. For example, cables from solar energy systems, air conditioning units, and mobile communication installations must be routed into buildings. Roof entries provide an effective solution for accommodating these utility lines.

Roof Entries for Flat Roof Installations

Hauff-Technik's swan neck roof entries are the ideal solution for installing cables and conduits on flat roofs. Engineered for durability and weather resistance through hot-dip galvanization, these entries effectively accommodate various cable types in the base area, similar to single house entries. The comprehensive system from Hauff-Technik is designed with modular components, providing exceptional flexibility during installation. This innovative system includes pipe bends, removable intermediate pieces, and extension pipes, along with a base pipe that is routed through the roof insulation. After installation, height adjustments are easily achievable, ensuring a customized fit for every project.

The swan neck design allows for continuous rotation of 360 degrees, enhancing its adaptability. The downward incline of the rounded pipes at the outlet improves weather resistance while optimizing the arrangement of cable bundles, effectively safeguarding against potential damage.

For insulated flat roofs equipped with two sealing membranes, a retrofitted roof entry is also a feasible option. This involves the use of two-level fixed/movable flanges, which Hauff-Technik offers for concrete embedding or as a variant for post-installation bolting. Each of these solutions adheres to the DIN 18531 standard, ensuring reliability and compliance. Made from stainless steel, these roof entries promise robustness and longevity.

Customers can choose between V2A and V4A stainless steel options. The V4A stainless steel variants offer superior resistance to chloride-containing substances due to their molybdenum alloy, making them particularly suitable for applications in the chemical industry or swimming pools. Just like gas house entries, these roof installations are designed to be both gas- and watertight.

Hauff-Technik's roof entries are available in a wide range of sizes. The gooseneck entries come with diameters from 100 to 300 mm, while the two-level fixed/movable flanges accommodate media pipes of up to 450 mm in diameter. The casing pipes are available in sizes ranging from 80 to 500 mm, facilitating seamless installation directly onto the respective pipe. Hauff-Technik also offers custom-designed roof entries tailored to meet specific customer requirements.

Sealing Systems for Roof Penetrations

The sealing of roof entries is an essential consideration in building construction. These seals must ensure a complete airtight and watertight fit for optimal performance over many years. Without proper sealing, buildings may suffer damage from rainwater infiltration or the condensation of humidity within the structure.

To effectively manage this issue, Hauff-Technik provides high-quality annular space seals. These seals play a vital role in various applications, including gas house entries, ensuring fully gas- and watertight transitions for house connections located on the roof. The cable sealing SKD by Hauff-Technik is particularly effective for gooseneck penetrations, crafted from durable EPDM rubber. This material is also employed in seals for single house entries, guaranteeing reliability. Furthermore, Hauff-Technik offers the option for custom-made annular space seals tailored to specific project needs.

A significant benefit of the annular space seals is their ability to accommodate multiple cables through a single unit. The number of cables that can be routed depends on the sealing system chosen, as well as the dimensions and types of cables. This versatility simplifies the installation of solar, HVAC, and telecommunication lines on the roof.

The design of Hauff-Technik’s system allows for easy retrofitting. Each roof entry comes with sealing inserts, ensuring they remain airtight even when not in use. This design allows for later installation of additional cables through previously unused roof penetrations, offering enhanced flexibility. As a result, this approach eliminates the need for costly and complex installations of new house entries for future expansions of roof-mounted technologies.

Easy and Quick Installation of Roof Entries by Hauff-Technik

The thoughtful design of Hauff-Technik’s roof entries ensures that the installation of cables and pipes can be completed swiftly and easily. This applies whether you’re working during the construction phase or adding components later. To install the HRD cable and pipe sealing, just a cordless screwdriver and a torque wrench will do. The process for retrofitting the two-level fixed/loose flange is equally simple, requiring only a punch, hammer, scissors or cutter, torque wrench, and socket set.